Voltage control unit LUN 2167.03-8 and LUN 2167.04-8



Technical Information

Voltage control unit LUN 2167.03-8 (LUN 2167.04-8), type marking by the manufacturer 3 GN 016 (4 GN 016) is designed for the control and protection of dynamostarter with nominal voltage 28 V and maximal excitation current 7A.

 

These parameters are assured in assembly with dynamostarter:

  

Nominal voltage and accuracy of regulation

28 ± 0,75 V

Output current

7 A

Range of regulated voltage in operating mode

27 – 29 V

Range of regulated voltage at overload and extreme temperatures

26 – 29 V

Range of operating temperatures

-55 to +60 °C

Range of temperatures in non-operating status

-60 to +85 °C

Allowed elevation duty operation

11 500 m (37 800 ft)

Allowed elevation out of operation

15 200 m (50 000 ft)

Protection

IP 10

Environment

WW 27

Mass

max. 1,2 kg

 